When a Worcester Bosch boiler starts not to run as it should, it can be frustrating not knowing whether the fault is for you to fix or if it’s an issue that requires attention from a Gas Safe engineer, or a new boiler.

More often than not, the Worcester Bosch boiler will close down, or on display, a fault code, or an error message will show. 

Get a fixed price in 20 seconds

What fuel does your boiler use

Compare Quotes 

Fill in the form if you want a call back to book a service or an annual service plan for £8.99

    What boiler service option would you like? (required)

    What are Worcester fault codes?

    Fault codes are used to code, so it is simple for a Gas Safe engineer to pinpoint the cause of the issue. You could be asked for the code which is showing on the display when you call the Gas Safe engineer.

    Worcester Bosch Boiler Issues, Errors, and Fault Codes Compare Boiler Quotes

    The Worcester Bosch manufacturer manual should list the fault codes and error codes that may show up on your boiler display.

    If you cannot find the manufacturer manual which came with your boiler and your boiler is showing a fault code, you can look through the information below to find out what the error code stands for.

    Broken Worcester Bosch boiler? Compare new boiler quotes now

    If you’re getting error codes on your Worcester Bosch boiler and you think it may be time for a new one, why not get a fixed-price boiler quote online now. If you are in an emergency and don’t have the full amount for a boiler you can spread the cost with boilers on finance.

    Worcester Bosch Fault Codes:

    FAULT DESCRIPTION CODES THAT WILL APPEAR ON YOUR BOILER DISPLAY:
    Blocking Error The boiler will stop operating but no fault code will appear. You can access the cause code by pressing the spanner/return button. The condition will clear once the fault clears. For instance, if the boiler is waiting for an area to cool, the error will clear automatically once the associated area has cooled down.
    Locking Error The boiler will flash a warning triangle and a fault code. It will also show a static cause code. You’ll need to press the boiler reset button to clear the code, but only after the boiler has been fixed.
    Fault Error The boiler will display an alphanumeric fault code to indicate the fault group.
    Cause Error A three-digit number that can be accessed via the info menu by pressing the spanner/return button during a blocking error or when in normal operating status. The cause code should flash on the display during a locking error.
    Maintenance Code A maintenance code is displayed with the letter H followed by a number. The fault won’t stop the boiler from working but it tells you that the boiler needs to be looked at by a qualified engineer.

     

    Worcester Bosch Boiler Shut Down Error Codes:

    FAULT CODE CAUSE CODE POSSIBLE ISSUE:
    9A 362 Incorrect Heat Control Module (HCM) has been fitted
    9U 233 Code plug is faulty or not connected
    B7 257 Need to replace control board
    C6 215 Fan running too fast
    C6 216 Fan running too slow
    C7 214 Fan not running at all
    C7 217 Fan not running or the airflow is blocked
    D1 240 Sensor wet or damaged – the boiler will usually block for 300 seconds before the fault code is displayed
    D1 241 Sensor is disconnected or damaged  – the boiler will usually block for 300 seconds before the fault code is displayed
    D1 286 Boiler overheating
    E2 222 Flow sensor shorted or damaged
    E2 223 Flow sensor damaged or disconnected
    E5 218 or 332 Primary flow sensor overheated
    E9 219 Main heat exchanger overheated
    E9 220 Maximum temperature sensor on main heat exchanger has failed
    E9 221 Maximum temperature sensor on main heat exchanger not recognised
    E9 224 Flue gas thermostat overheated
    EA 227 Failure of four ignition attempts – Need to wait at least 30 seconds before another attempt is made
    EA 229 Established flame has been extinguished – Could be caused by a blocked sump or strong wind into the flue
    EA 234 Gas valve coil disconnected
    EA 261 No flame established during the first 4 seconds of ignition period
    EA 338 Pump not detecting water – check pressure gauge and re-pressurise to 1 bar

     

    Worcester Bosch Boiler Blocking Fault Codes:

    FAULT CODE CAUSE CODE POSSIBLE CAUSE
    A1 281 Low or no water in the system  – check pressure gauge and re-pressurise to 1 bar
    C1 264 Fan stopped working
    EA 227 No flame detected – boiler will block during 4 attempts before going to a locking fault
    EF 349 Boiler operating at minimum burner load and there is a greater flow and return temperature than 18°C
    No code 212 or 213 Airlock or reduced water content – check pressure gauge and re-pressurise to 1 bar
    No code 260 Sensor disconnected or no water content – check pressure gauge and re-pressurise to 1 bar

    Worcester Bosch 4000 error codes

    Error codes for the new Worcester Bosch 4000 boilers

    fault\error Code Error Meaning
    Code: 1021Cylinder charging or hot water temperature sensor faulty. 

    The hot water sensor has been changed if an open or short circuit or refitted to the pipe if it has fallen off. Turn the appliance off and back on again.
    Code: 224Arrange a visit from a Worcester Bosch engineer to reset the boiler/PCB. This is a software issue.

     

    Worcester Bosch Greenstar CDi Classic Combi Error Codes:

    Greenstar CDi Classic combi boiler error codes

    FAULT CODE DESCRIPTION
    A7 Hot water NTC sensor defective
    A8 Break in communication to FX controls
    b1 Code plug not detected
    C6 Fan speed too low
    E2 CH flow NTC sensor defective
    E9 Safety temperature limiter in CH flow has tripped
    EA Flame not detected. If safe, check that the gas is on in the house OR check for a frozen condensate pipe. Could be a blocked flue outlet – contact a Gas Safe engineer
    F0 Internal error
    F7 Flame detected even though boiler is switched off
    FA Flame detected after the gas has been shut off
    Fd Reset button pressed by mistake

     

    Worcester Bosch Greenstar CDi Highflow Combi Error Codes:

    FAULT CODE DESCRIPTION
    A7 Hot water NTC sensor defective
    A8 Break in communication to weather compensating clip-in control of Greenstar Comfort II RF
    B1 Code plug not detected
    C6 Fan speed too low
    D5 Condensate pipe fault
    E2 CH flow NTC sensor defective
    E9 Safety temperature limiter in CH flow has tripped
    EA Flame not detected. If safe, check that the gas is on in the house OR check for a frozen condensate pipe. Could be a blocked flue outlet – contact a Gas Safe engineer
    F0 Internal error
    F7 Flame detected even though boiler is switched off
    FA Flame detected after gas shut off
    Fd Reset button pressed by mistake
    SE Service required
    U1, U2 or U3 Boiler flow temperature is too high and the boiler will shut down until it has cooled down

     

    Worcester Greenstar Heatslave II Oil Combi Error Codes:

    FAULT CODE CAUSE CODE DESCRIPTION
    E9 210 Maximum temperature thermostat or air pressure witch activated. Reset overheat thermostat or air pressure switch before resetting boiler
    E5 218 Flow temperature too high
    E9 219, 220 or 221 Safety temperature too high, safety sensor short circuit or safety sensor open circuit
    E2 222, 223 or 233 Flow sensor short circuit, flow sensor open circuit or heat control module code plug missing or defective
    F0 237 or 238 Software relay error – Resistors between plus X4 pins 3 & 5 disconnected or water in the burner control box
    F0 239 or 259 Watchdog relay error or A/D reference relay error – If error persists, change the control board
    F0 263 Appliance powered off with locking fault present – press reset button to clear
    D4 271 Temperature difference between flow and safety sensors exceeds the limit
    E9 276 or 277 Flow temperature or safety temperature exceeds 95°C
    F0 278, 279 or 290 Sensor test error, A/D convertor error or A/D convertor reference error
    E5 332 Primary flow has exceeded 105°C – primary sensor overheated
    9A 360 Incorrect HCM for boiler variant – replace with correct HCM
    A7 808 DHW sensor defective – check and replace defect sensor as necessary
    A0 809 Thermal store sensor defective – check and replace defect sensor as necessary
    9F 855 or 856 Burner lockout or 5 burner lockouts repeated resets. Check the burner and fuel supply, and ensure oil supply is free of contaminants. After five 855 burner lockouts, code 856 is displayed.
    H29 N/A Warning triangle and house symbol displayed on controller – weather compensation activated but no weather sensor detected. Refer to section 5.11 on page 32 of manual
    H27 N/A Warning triangle symbol displayed on controller – DCW in sensor defect

    Worcester Bosch Greenstar CDi Classic System Error Codes:

    FAULT CODE DESCRIPTION
    b1 Code plug not detected
    C6 Fan speed too low
    E9 Safety temperature limiter in CH flow has tripped
    EA Flame not detected. If safe, check that the gas is on in the house OR check for a frozen condensate pipe. Could be a blocked flue outlet – contact a Gas Safe engineer
    F0 Internal error
    F7 Flame detected even though boiler is switched off
    FA Flame detected after gas shut off
    Fd Reset button pressed by mistake

    Worcester Bosch GB162 System Error Codes:

    FAULT CODE CAUSE CODE DESCRIPTION
    N/A 208 Boiler is in chimney sweep mode
    N/A 200 Boiler is in heating mode
    N/A 201 Boiler is in domestic hot water mode
    N/A 202 Boiler is waiting because there is a heat demand from the on/off or modulating control
    N/A 203 Boiler is on standby
    N/A 204 Boiler is waiting because the actual temperature is higher than the calculated or selected temperature
    N/A 212 The temperature recorded by the flow temperature sensor or safety sensor is rising too fast
    N/A 226 Diagnoses tool was connected and is now locked out
    N/A 260 The flow temperature sensor is not detecting a rise in temperature after a burner start
    N/A 265 Boiler is waiting in response to a heat demand – boiler regularly switches to partial load
    N/A 268 Component test phase
    N/A 270 Boiler is modulating upwards
    N/A 283 Boiler is preparing for a burner start – fan and pump activated
    N/A 284 Gas valve is switched on
    N/A 305 Boiler is waiting for domestic hot water operation to finish
    N/A 235 The KIM (boiler identification module) is too new for burner control unit
    N/A 360 The fitted KIM is not compatible with the burner control unit
    9A 361 The fitted burner control unit is not compatible with the KIM
    9U 233 The burner control unit or KIM is faulty
    A3 317 Short circuit in the flue gas temperature sensor contacts
    B7 257 Burner control unit or KIM is faulty
    C1 264 No power or control signal to supply the fan
    C4 276 Boiler switched off for a max of 2 minutes because it has been operating non-stop for 24 hours
    C6 215 Fan speed too high
    C6 216 Fan speed too low
    C7 214 Fan doesn’t run during start phase
    C7 217 Fan speed is irregular on start up
    CE 207 Water pressure too low
    CE 266 Pump test failed
    D1 240 Interruption to contacts of boiler return temperature sensor
    D3 232 External switching contact is open
    D4 213 Temperature recorded by the flow temperature sensor or return temperature sensor is rising too fast
    D4 271 Temperature differential between flow and safety temperature sensor is too high
    D4 286 Boiler return temperature sensor has detected a return temperature higher than 105°C
    E2 222 Short circuit in flow temperature sensor contacts
    E2 223 Interruption to flow temperature sensor contacts
    E5 218 Temperature sensed by flow temperature sensor is higher than 105°C
    E9 210 Temperature measured by flue gas sensor is open and too high
    E9 219 Safety temperature sensor has sensed a temperature higher than 105°C
    E9 220 Contacts for the safety temperature sensor have shorted or the safety temperature sensor has detected a temperature that exceeds 105°C
    E9 224 Interruption to the safety temperature sensor
    E9 276 Temperature flow sensor has sensed a temperature higher than 95°C
    E9 277 Safety temperature sensor has sensed a temperature higher than 95°C
    E9 285 Boiler temperature sensor has sensed a temperature higher than 95°C
    E9 318 Interruption to flue gas sensor contacts
    EA 227 Insufficient ionisation current measured following ignition of burner
    EA 229 Insufficient ionisation current detected by system during the burning phase
    EA 234 Interruption to contact of the gas valve
    EA 261 Faulty burner control unit
    EA 269 Ignition device activated for too long
    F0 238 Faulty burner control unit (KIM)
    F0 239 Error with burner control unit (KIM)
    F0 242 to 253 and 255, 259, 263, 267 and 272 Faulty burner control unit (KIM)
    F0 278 Sensor test failed – check cabling and plug sensors
    F0 279 Faulty burner control unit or KIM – may need to replace control unit
    F0 280 Faulty burner control unit
    F0 287 Error with burner control unit or KIM
    F0 290 Faulty burner control unit or KIM
    F7 228 Ionisation current measured before burner started
    F7 328 Power failure occurred
    FA 306 Ionisation current measured after burner went out
    FD 231 Interruption to mains voltage during interlocking fault
    EC 256 Burner control unit error
    EH 258 Faulty burner control unit – check plug and wiring
    H07   Water pressure too low
    HrE   Boiler keeps resetting
    rE   Boiler resets

    Worcester Bosch Boiler Issues, Errors, and Fault Codes Compare Boiler Quotes

     

    Borken Worcester Bosch? Get a new Worcester boiler quote here

    Hopefully, our guide has helped you figure out what the issue is. If you need more help, try the Worcester Bosch site. If you need a new boiler and want to find out how much new boiler costs, however, we can help you get a brand new boiler installed tomorrow, all at a fixed price.

    Get a fixed price in 20 seconds

    What fuel does your boiler use

    Compare Quotes 

    What our customers think

    5 Stars on Trustpilot

    Would recommend

    Stressed when needed a new boiler but easy process with affordable finance. New boiler installed within a few days with option for next day.


    Paul Jones 5 Star on Trustpilot

    We were very impressed

    On the day, they came on time. Lovely people, they kept everything clean. Explained everything to me. No mess, kept me informed.


    Anne Cross 5 Star on Trustpilot

    Great Experience

    Great experience - quick to arrange, easy to work with the very responsive online team and all installed faster than expected.


    Ms Baxter 5 Star on Trustpilot


    Layout Curve
    Next Day Fitting Till 2pm! & £50 Off Fixed Online PricesGet Your Prices >