Potterton Boiler Fault & Error Codes

Potterton Boiler Faults & Error Codes

Potterton Boiler Fault & Error Codes

Boilers are like cars, a problem could occur when you least expect it for no apparent reason. Potterton boilers are no different.

Part of the Baxi family, these boilers are few and far between these days but they are still powering homes in the UK

Potterton Boiler Fault & Error Codes Compare Boiler Quotes

The fault codes you will see on a Potterton boiler are a letter and a number, they are designed to show up on your boiler display so you can go check on the Potterton website or the table below and see if it is a problem you can solve.

If the fault code shows an error which you cannot solve, contact a Gas Safe registered engineer as soon as possible.

Get a fixed price in 20 seconds

What fuel does your boiler use

Compare Quotes 

    What boiler service option would you like? (required)

    Potterton Boiler Fault Code Table:

    If you’ve got an error code on a Potterton boiler then it should be in our list. Most of the best combi boilers in the UK will show an error at some point in their lifetime. 

    If you have an old boiler, you may want to consider the fact it may be time to upgrade to a new A-rated combi boiler to help keep running costs down. You can get a fixed price for a boiler online on all the best combis, system boilers and regular boilers in the UK

    Assure Combi Boiler Fault Codes

    FAULT CODE DESCRIPTION / POSSIBLE CAUSE
    E09 Gas valve connection cable.
    E10 External probe fault.
    E12 Differential water flow switch fault (still open).
    E13 Differential water flow switch fault (still closed).
    E15 Gas valve command fault.
    E20 Central heating NTC fault.
    E28 Flue NTC fault.
    E40 Central heating return NTC fault.
    E50 Domestic hot water (DHW) NTC sensor fault (tank boiler) (s.c.) or DHW NTC sensor fault (tank boiler) (o.c.).
    E83, E84, E85, E86 or E87 No communication.
    E190 Pre-circulation fault.
    E110 Boiler max temperature exceeded for gradient (could be a jammed pump or air in the circuit) or boiler maximum temperature exceeded for overtemperature (could be jammed pump or air in the circuit) or the safety thermostat has tripped.
    E118 Primary system water pressure is too low.
    E125 Circulation fault (primary).
    E128 Frequent flame failure – 12 times.
    E129 Safety error for frequent loss of flame with maximum correction during the ignition during calibration function.
    E130 Flue thermostat sensor has tripped (lockout).
    E133 Failure to light (could be an issue with gas supply). Check that the gas supply is available by lighting your gas fire or cooker.
    E134 Elapsed time gas valve open without gas (short request in a short period).
    E135 Interruption of gas supply (internal error).
    E154 Flow/return sensor temperature test.
    E160 Fault with fan or fan wiring.
    E163 Domestic hot water (DHW) NTC sensor fault (s.c.) or DHW NTC sensor fault (o.c.).
    E270 Circulation fault (dry fire).
    E317 Wrong power supply electrical frequency (Hz).
    E321 Hot water NTC fault.
    E384 False flame.
    E385 Under voltage.
    E430 Water pressure temporary test.
    E430 + flame crossed Water pressure test failed.

    Promax Ultra Boiler Fault Codes

    FAULT CODE DESCRIPTION / POSSIBLE CAUSE
    E09 Gas valve wiring fault.
    E10 Outdoor sensor error.
    E15 Gas valve connection fault.
    E20 Central heating thermistor sensor fault.
    E28 Flue thermistor fault.
    E40 Central heating return thermistor fault.
    E50 Domestic hot water sensor fault.
    E53 Flue obstruction.
    E55 Calibration required.
    E78 Water pressure sensor fault.
    E83, E84, E85, E86 or E87 No communication between boiler and room controller.
    E92 Combustion test alarm during auto-setting.
    E109 Poor circulation.
    E110 Boiler overheat has tripped.
    E117 System pressure too high.
    E118 System pressure too low.
    E125 Primary water circulation fault.
    E128 Loss of flame during operation.
    E129 Loss of flame during calibration.
    E130 Flue thermostat sensor has tripped (lockout).
    E133 Ignition fault.
    E135 Internal error.
    E154 Primary flow fault.
    E160 Fault with fan.
    E270 Dry fire.
    E317 Wrong power supply (HZ).
    E321 Hot water thermistor fault.
    E384 Flame detected when gas valve off (false flame).
    E385 Low voltage – less than 195v.

    Potterton Promax Combi, System and Store Boiler Fault Codes

    FAULT CODE DESCRIPTION / POSSIBLE CAUSE
    E10 Outdoor sensor error.
    E20 Central heating thermistor sensor fault.
    E28 Flue thermistor fault.
    E50 Domestic hot water sensor fault.
    E110 Boiler overheat has tripped.
    E119 System pressure too low.
    E125 Primary water circulation fault.
    E130 Flue thermistor sensor has tripped (lockout).
    E131 Flue overheat lockout.
    E133 Ignition fault.
    E151 or E152 PCB error.
    E160 or E161 Fault with fan.
    E164 Domestic hot water sensor error (UK) or heating flow switch error (ROI).
    E167 PCB fault.
    E168 PCB lockout.
    E193 Circulation error.

    Gold Combi, Gold System and Titanium Combi Boiler Fault Codes

    FAULT CODE DESCRIPTION / POSSIBLE CAUSE
    E09 Gas valve wiring fault.
    E10 Outdoor sensor error.
    E15 Gas valve connection fault.
    E20 Central heating thermistor sensor fault.
    E28 Flue thermistor fault.
    E40 Central heating return thermistor fault.
    E50 Domestic hot water sensor fault.
    E53 Flue obstruction.
    E55 Calibration required.
    E78 Water pressure sensor fault.
    E83, E84, E85, E86 or E87 No communication between boiler and room controller.
    E92 Combustion test alarm during auto-setting.
    E109 Poor circulation.
    E110 Boiler overheat has tripped.
    E117 System pressure too high.
    E118 System pressure too low.
    E125 Primary water circulation fault.
    E128 Loss of flame during operation.
    E129 Loss of flame during calibration.
    E130 Flue thermostat sensor has tripped (lockout).
    E133 Ignition fault.
    E135 Internal error.
    E154 Primary flow fault.
    E160 Fault with fan.
    E270 Dry fire.
    E317 Wrong power supply (HZ).
    E321 Hot water thermistor fault.
    E384 Flame detected when gas valve off (false flame).
    E385 Low voltage – less than 195v.

    If you need any more assistance check out the Potterton website now.

    Get a fixed price in 20 seconds

    What fuel does your boiler use

    Compare Quotes 

    What our customers think

    5 Stars on Trustpilot

    Would recommend

    Stressed when needed a new boiler but easy process with affordable finance. New boiler installed within a few days with option for next day.


    Paul Jones 5 Star on Trustpilot

    We were very impressed

    On the day, they came on time. Lovely people, they kept everything clean. Explained everything to me. No mess, kept me informed.


    Anne Cross 5 Star on Trustpilot

    Great Experience

    Great experience - quick to arrange, easy to work with the very responsive online team and all installed faster than expected.


    Ms Baxter 5 Star on Trustpilot


    Layout Curve
    Next Day Fitting Till 2pm! & £50 Off Fixed Online PricesGet Your Prices >